Correcting atmospheric CO2 and CH4 mole fractions obtained with Picarro analyzers for sensitivity of cavity pressure to water vapor

Friedemann Reum1, Christoph Gerbig1, Jost V. Lavric1, Chris W. Rella2, and Mathias Göckede1 Friedemann Reum et al.
  • 1Max Planck Institute for Biogeochemistry, Jena, Germany
  • 2Picarro Inc., Santa Clara, CA, USA

Abstract. Measurements of dry air mole fractions of atmospheric greenhouse gases are used in inverse models of atmospheric tracer transport to quantify their sources and sinks. The measurements have to be calibrated to a common scale to avoid bias in the inferred fluxes. For this purpose, the World Meteorological Organization (WMO) has set requirements for the inter-laboratory compatibility of atmospheric greenhouse gas (GHG) measurements. A widely used series of devices for these measurements are the GHG analyzers manufactured by Picarro, Inc. These are often operated in humid air, and the effects of water vapor are corrected for in post-processing. Here, we report on rarely detected and previously unexplained biases of the water correction method for CO2 and CH4 in the literature. They are largest at water vapor mole fractions below 0.5% H2O, which were undersampled in previous studies, and can therefore affect measurements obtained in humid air and in air dried with a Nafion membrane. The biases, which can amount to considerable fractions of the WMO goals, are caused by a sensitivity of the pressure in the measurement cavity to water vapor. We correct these biases by modifying the water correction method from the literature. Our method relies on experiments that maintain stable water vapor levels to allow equilibration of cavity pressure. The commonly used droplet method does not fulfill this requirement. Correcting CO2 measurements proved challenging, presumably because of our humidification method. Open questions pertain to differences between analyzers and variability over time. Correcting the cavity pressure-related biases helps keeping the overall accuracy of measurements of dry air mole fractions of CO2 and CH4 obtained with Picarro GHG analyzers in humid and Nafion-dried air within the WMO goals.

Download & links
Friedemann Reum et al.
Interactive discussion
Status: open (until 18 Oct 2018)
Status: open (until 18 Oct 2018)
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment
[Subscribe to comment alert] Printer-friendly Version - Printer-friendly version Supplement - Supplement
Friedemann Reum et al.
Friedemann Reum et al.
Viewed
Total article views: 473 (including HTML, PDF, and XML)
HTML PDF XML Total Supplement BibTeX EndNote
378 91 4 473 20 6 9
  • HTML: 378
  • PDF: 91
  • XML: 4
  • Total: 473
  • Supplement: 20
  • BibTeX: 6
  • EndNote: 9
Views and downloads (calculated since 21 Aug 2018)
Cumulative views and downloads (calculated since 21 Aug 2018)
Viewed (geographical distribution)
Total article views: 473 (including HTML, PDF, and XML) Thereof 469 with geography defined and 4 with unknown origin.
Country # Views %
  • 1
1
 
 
 
 
Cited
Saved
No saved metrics found.
Discussed
No discussed metrics found.
Latest update: 18 Sep 2018
Publications Copernicus
Download
Short summary
High-accuracy observations of atmospheric CO2 and CH4 mole fractions are often obtained using Picarro greenhouse gas analyzers. We report biases in CO2 and CH4 mole fractions that are related to pressure changes in the optical cavity and occur mainly at low water vapor mole fractions. We provide a method to correct the biases, which contributes to keeping the overall accuracy of CO2 and CH4 measurements with Picarro analyzers within the WMO inter-laboratory compatibility goals.
High-accuracy observations of atmospheric CO2 and CH4 mole fractions are often obtained using...
Citation
Share