Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union

Journal metrics

  • IF value: 3.089 IF 3.089
  • IF 5-year<br/> value: 3.700 IF 5-year
    3.700
  • CiteScore<br/> value: 3.59 CiteScore
    3.59
  • SNIP value: 1.273 SNIP 1.273
  • SJR value: 2.026 SJR 2.026
  • IPP value: 3.082 IPP 3.082
  • h5-index value: 45 h5-index 45
https://doi.org/10.5194/amt-2018-24
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.
Research article
12 Feb 2018
Review status
This discussion paper is a preprint. It is a manuscript under review for the journal Atmospheric Measurement Techniques (AMT).
Folded Tubular Photometer for atmospheric measurements of NO2 and NO
John W. Birks1, Peter C. Andersen1, Craig J. Williford1, Andrew A. Turnipseed1, Stanley E. Strunk1, Christine A. Ennis1, and Erick Mattson2 12B Technologies, Inc., 2100 Central Ave., Suite 105, Boulder, CO 80301, USA
2Colorado Dept. of Public Health and Environment, Air Pollution Control Division/Technical Services Program, 4300 Cherry Creek Drive South, Denver, CO 80246, USA
Abstract. We describe and characterize a modular Folded Tubular Photometer for making direct measurements of the concentrations of air pollutants such as nitrogen dioxide (NO2), sulfur dioxide (SO2), ozone (O3), and black carbon particulate matter. Direct absorbance measurements using this photometer can be made across the spectral range from the ultraviolet (UV) to the near-infrared. The absorbance cell makes use of modular components (tubular detection cells and mirror cubes) that allow construction of path lengths of up to 2 meters or more while maintaining low cell volumes. The long path lengths and low cell volumes enable sensitive detection of ambient air pollutants down to low part-per-billion levels for gas species and aerosol extinctions down to 1 Mm−1, corresponding to ~ 0.1 μg m−3 for black carbon particulates. Pressure equalization throughout the stages of the absorbance measurement is shown to be critical to accurate measurements of analyte concentrations. The present paper describes the application of this photometer to direct measurements of nitrogen dioxide (NO2) and the incorporation of design features that also enable measurement of nitric oxide (NO) in the same instrument. Excellent agreement for ambient measurements along an urban roadside was found for both NO2 and NO measured by the Folded Tubular Photometer compared to existing standard techniques. Compared to commonly used methods for measurements of NOx species, the advantages of this approach include 1) an absolute quantification for NO2 based on the Beer-Lambert Law, thereby greatly reducing the frequency at which calibrations are required; 2) the direct measurement of NO2 concentration without prior conversion to NO as is required for the commonly used chemiluminescence method; 3) the use of modular components that allow construction of absorbance detection cells of varying lengths for extending the dynamic range of concentrations that can be measured; 4) a more economical instrument than other currently available direct measurement techniques for NO2; and 5) the potential for simultaneous detection of additional species such as SO2, O3, and black carbon in the same instrument. In contrast to other commercially available direct NO2 measurements, such as cavity-attenuated phase shift spectroscopy (CAPS), the Folded Tubular Photometer provides a means for measuring NO simultaneously in the same apparatus by quantitatively converting NO to NO2 with ozone, which is then detected by direct absorbance.

Citation: Birks, J. W., Andersen, P. C., Williford, C. J., Turnipseed, A. A., Strunk, S. E., Ennis, C. A., and Mattson, E.: Folded Tubular Photometer for atmospheric measurements of NO2 and NO, Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2018-24, in review, 2018.
John W. Birks et al.
John W. Birks et al.
John W. Birks et al.

Viewed

Total article views: 187 (including HTML, PDF, and XML)

HTML PDF XML Total BibTeX EndNote
139 42 6 187 2 6

Views and downloads (calculated since 12 Feb 2018)

Cumulative views and downloads (calculated since 12 Feb 2018)

Viewed (geographical distribution)

Total article views: 187 (including HTML, PDF, and XML)

Thereof 186 with geography defined and 1 with unknown origin.

Country # Views %
  • 1

Saved

Discussed

Latest update: 20 Feb 2018
Publications Copernicus
Download
Short summary
A modular long-path Folded Tubular Photometer for making absorbance measurements of air pollutant concentrations is described. The present paper applies this photometer to direct measurements of nitrogen dioxide and, indirectly, to nitric oxide. Excellent agreement for both was observed for measurements along an urban roadside compared with existing standard techniques. Advantages and extension of this technique to other atmospheric pollutants, including particulates, are discussed.
A modular long-path Folded Tubular Photometer for making absorbance measurements of air...
Share