Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union

Journal metrics

  • IF value: 3.089 IF 3.089
  • IF 5-year<br/> value: 3.700 IF 5-year
    3.700
  • CiteScore<br/> value: 3.59 CiteScore
    3.59
  • SNIP value: 1.273 SNIP 1.273
  • SJR value: 2.026 SJR 2.026
  • IPP value: 3.082 IPP 3.082
  • h5-index value: 45 h5-index 45
https://doi.org/10.5194/amt-2017-419
© Author(s) 2018. This work is distributed under
the Creative Commons Attribution 4.0 License.
Research article
02 Jan 2018
Review status
This discussion paper is a preprint. It is a manuscript under review for the journal Atmospheric Measurement Techniques (AMT).
Characterization of a catalyst-based total nitrogen and carbon conversion technique to calibrate particle mass measurement instrumentation
Chelsea E. Stockwell1,2, Agnieszka Kupc1,2, Bartlomiej Witkowski1,2,3, Ranajit K. Talukdar1,2, Yong Liu4, Vanessa Selimovic5, Kyle J. Zarzana1,2, Kanako Sekimoto1,2, Carsten Warneke1,2, Rebecca A. Washenfelder1, Robert J. Yokelson5, Ann M. Middlebrook1, and James M. Roberts1 1NOAA Earth System Research Laboratory (ESRL), Chemical Sciences Division, Boulder, CO 80305, USA
2Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO 80309, USA
3University of Warsaw, Faculty of Chemistry, al. Żwirki i Wigury 101, 02-089, Warsaw, Poland
4University of Colorado Denver, Department of Chemistry, Denver, CO 80217, USA
5University of Montana, Department of Chemistry, Missoula, MT 59812, USA
Abstract. The chemical composition of aerosol particles is a key aspect in determining their impact on the environment. For example, nitrogen (N)-containing particles impact atmospheric chemistry, air quality, and ecological N-deposition. Instruments that measure total reactive nitrogen (Nr = all nitrogen compounds except for N2 and N2O) focus on gas-phase nitrogen and very few studies directly discuss the instrument capacity to measure the mass of Nr–containing particles. Here, we investigate the mass quantification of particle-bound nitrogen using a custom Nr system that involves total conversion to nitric oxide (NO) across platinum and molybdenum catalysts followed by NO-O3 chemiluminescence detection. We evaluate the particle conversion of the Nr instrument by comparing to mass derived concentrations of size-selected and counted ammonium sulfate ((NH4)2SO4), ammonium nitrate (NH4NO3), ammonium chloride (NH4Cl), sodium nitrate (NaNO3), and ammonium oxalate ((NH4)2C2O4) particles determined using instruments that measure particle number and size. These measurements demonstrate Nr-particle conversion across the Nr catalysts that is independent of particle size with 98 ± 10 % efficiency for 100–600 nm particle diameters. We also show conversion of particle-phase organic carbon species to CO2 across the instrument’s platinum catalyst followed by a non-dispersive infrared (NDIR) CO2 detector. We show the Nr system is an accurate particle mass measurement method and demonstrate its ability to calibrate particle mass measurement instrumentation using single component, laboratory generated, Nr-containing particles below 2.5 µm in size. In addition we show agreement with mass measurements of an independently calibrated on-line particle-into-liquid sampler directly coupled to the electrospray ionization source of a quadrupole mass spectrometer (PILS-ESI/MS) sampling in the negative ion mode. We obtain excellent correlations (R2 = 0.99) of particle mass measured as Nr with PILS-ESI/MS measurements converted to the corresponding particle anion mass (e.g. nitrate, sulfate, and chloride). The Nr and PILS-ESI/MS are shown to agree to within ~ 6 % for particle mass loadings up to 120 µg m−3. Consideration of all the sources of error in the PILS-ESI/MS technique yields an overall uncertainty of ±20 % for these single component particle streams. These results demonstrate the Nr system is a reliable direct particle mass measurement technique that differs from other particle instrument calibration techniques that rely on knowledge of particle size, shape, density, and refractive index.

Citation: Stockwell, C. E., Kupc, A., Witkowski, B., Talukdar, R. K., Liu, Y., Selimovic, V., Zarzana, K. J., Sekimoto, K., Warneke, C., Washenfelder, R. A., Yokelson, R. J., Middlebrook, A. M., and Roberts, J. M.: Characterization of a catalyst-based total nitrogen and carbon conversion technique to calibrate particle mass measurement instrumentation, Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2017-419, in review, 2018.
Chelsea E. Stockwell et al.
Chelsea E. Stockwell et al.
Chelsea E. Stockwell et al.

Viewed

Total article views: 164 (including HTML, PDF, and XML)

HTML PDF XML Total Supplement BibTeX EndNote
128 34 2 164 8 2 2

Views and downloads (calculated since 02 Jan 2018)

Cumulative views and downloads (calculated since 02 Jan 2018)

Viewed (geographical distribution)

Total article views: 164 (including HTML, PDF, and XML)

Thereof 164 with geography defined and 0 with unknown origin.

Country # Views %
  • 1

Saved

Discussed

Latest update: 16 Jan 2018
Publications Copernicus
Download
Short summary
This work investigates the total conversion of particle-bound nitrogen and organic carbon across platinum and molybdenum catalysts followed by NO-O3 chemiluminescence and non-dispersive infrared CO2 detection. We show the instrument is an accurate particle mass measurement method and demonstrate its ability to calibrate particle mass measurement instrumentation through comparisons with a calibrated particle-into-liquid sampler coupled to an electrospray ionization source of a mass spectrometer.
This work investigates the total conversion of particle-bound nitrogen and organic carbon across...
Share