Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union

Journal metrics

  • IF value: 3.089 IF 3.089
  • IF 5-year<br/> value: 3.700 IF 5-year
    3.700
  • CiteScore<br/> value: 3.59 CiteScore
    3.59
  • SNIP value: 1.273 SNIP 1.273
  • SJR value: 2.026 SJR 2.026
  • IPP value: 3.082 IPP 3.082
  • h5-index value: 45 h5-index 45
https://doi.org/10.5194/amt-2016-413
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.
Research article
23 Feb 2017
Review status
This discussion paper is a preprint. A revision of the manuscript is under review for the journal Atmospheric Measurement Techniques (AMT).
SEALDH-II – a calibration-free transfer standard for airborne water vapor measurements: Pressure dependent absolute validation from 5–1200 ppmv at a metrological humidity generator
Bernhard Buchholz1,2,a and Volker Ebert1,2,3 1Physikalisch-Technische Bundesanstalt Braunschweig, Germany
2Physikalisch Chemisches Institut, Universität Heidelberg, Germany
3Center of Smart Interfaces, Technische Universität Darmstadt, Germany
acurrently at: Department of Civil and Environmental Engineering, Princeton University, USA
Abstract. Highly accurate water vapor measurements are indispensable for understanding a variety of scientific questions as well as industrial processes. While in metrology water vapor concentrations can be defined, generated and measured with relative uncertainties in the single percentage range, field deployable airborne instruments deviate even under quasi-static laboratory conditions up to 10–20 %. The novel SEALDH-II hygrometer, a calibration-free, tuneable diode laser spectrometer, bridges this gap by implementing an entirely new concept to achieve higher accuracy levels in the field. Here we present the absolute validation of SEALDH-II at a traceable humidity generator during 23 days of permanent operation at 15 different H2O concentration levels between 5 and 1200 ppmv. At each concentration level, we studied the pressure dependence at 6 different gas pressures between 65 and 950 hPa. Further, we describe the setup for this metrological validation, the challenges to overcome when assessing water vapor measurements on a high accuracy level, as well as the comparison results. With this validation, SEALDH-II is the first metrologically validated humidity transfer standard which links several scientific airborne and laboratory measurement campaigns to the international metrological water vapor scale.

Citation: Buchholz, B. and Ebert, V.: SEALDH-II – a calibration-free transfer standard for airborne water vapor measurements: Pressure dependent absolute validation from 5–1200 ppmv at a metrological humidity generator, Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2016-413, in review, 2017.
Bernhard Buchholz and Volker Ebert
Bernhard Buchholz and Volker Ebert
Bernhard Buchholz and Volker Ebert

Viewed

Total article views: 312 (including HTML, PDF, and XML)

HTML PDF XML Total BibTeX EndNote
230 52 30 312 19 23

Views and downloads (calculated since 23 Feb 2017)

Cumulative views and downloads (calculated since 23 Feb 2017)

Viewed (geographical distribution)

Total article views: 312 (including HTML, PDF, and XML)

Thereof 312 with geography defined and 0 with unknown origin.

Country # Views %
  • 1

Saved

Discussed

Latest update: 24 Nov 2017
Publications Copernicus
Download
Short summary
This paper describes the absolute validation of the novel, calibration-free SEALDH-II hygrometer at a traceable humidity generator. During 23 days of permanent operation, 15 H2O concentration levels (5–1200 ppmv) at 6 gas pressures (65–950 hPa) were validated. With this validation, SEALDH-II is the first metrologically validated humidity transfer standard which links several scientific airborne and laboratory measurement campaigns to the international metrological water vapor scale.
This paper describes the absolute validation of the novel, calibration-free SEALDH-II hygrometer...
Share