Journal cover Journal topic
Atmospheric Measurement Techniques An interactive open-access journal of the European Geosciences Union

Journal metrics

  • IF value: 3.089 IF 3.089
  • IF 5-year<br/> value: 3.700 IF 5-year
    3.700
  • CiteScore<br/> value: 3.59 CiteScore
    3.59
  • SNIP value: 1.273 SNIP 1.273
  • SJR value: 2.026 SJR 2.026
  • IPP value: 3.082 IPP 3.082
  • h5-index value: 45 h5-index 45
https://doi.org/10.5194/amt-2017-90
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.
Research article
16 May 2017
Review status
This discussion paper is under review for the journal Atmospheric Measurement Techniques (AMT).
Intercomparison of Pandora Stratospheric NO2 Slant Column Product with the NIWA M07 NDACC Standard
Travis N. Knepp1,2, Richard Querel3, Paul Johnston3, Larry Thomason2, David Flittner2, and Joseph M. Zawodny2 1Science Systems and Applications Inc., Hampton, VA, 23666 USA
2NASA Langley Research Center, Hampton, VA, 23681 USA
3National Institute of Water and Atmospheric Research, Lauder, Central Otago, New Zealand
Abstract. In September 2014 a Pandora multi-spectral photometer operated by the SAGE-III project was sent to Lauder, New Zealand to operate side-by-side with the National Institute of Water and Atmospheric Research's (NIWA) Network for Detection of atmospheric Composition Change (NDACC) standard zenith slant column NO2 instrument to allow intercomparison between the two instruments, and evaluation of the Pandora unit as a potential SAGE-III validation tool for stratospheric NO2. This intercomparison spanned a full year, from September 2014–September 2015. Both datasets were produced using their respective native algorithms using a common reference spectrum (i.e. 12:00 on 26 February 2015). Throughout the entire deployment period both instruments operated in a zenith-only observation configuration. Though conversion from slant column density (SCD) to vertical-column density is routine (by application of an air mass factor), we limit the current analysis to SCD only. This omission is beneficial in that it provides a strict intercomparison of the two instruments and the retrieval algorithms as opposed to introducing an AMF-dependence in the intercomparison as well. It was observed that the current hardware configurations and retrieval algorithms are in good agreement (R > 0.95). The detailed results of this investigation are presented herein.

Citation: Knepp, T. N., Querel, R., Johnston, P., Thomason, L., Flittner, D., and Zawodny, J. M.: Intercomparison of Pandora Stratospheric NO2 Slant Column Product with the NIWA M07 NDACC Standard, Atmos. Meas. Tech. Discuss., https://doi.org/10.5194/amt-2017-90, in review, 2017.
Travis N. Knepp et al.
Travis N. Knepp et al.
Travis N. Knepp et al.

Viewed

Total article views: 252 (including HTML, PDF, and XML)

HTML PDF XML Total BibTeX EndNote
189 53 10 252 2 17

Views and downloads (calculated since 16 May 2017)

Cumulative views and downloads (calculated since 16 May 2017)

Viewed (geographical distribution)

Total article views: 252 (including HTML, PDF, and XML)

Thereof 250 with geography defined and 2 with unknown origin.

Country # Views %
  • 1

Saved

Discussed

Latest update: 24 Jun 2017
Publications Copernicus
Download
Short summary
The SAGE-III instrument was launched in February 2017. As with any new instrument, a significant post-launch activity is planned to validate the data products. Validation of trace gases with short photolytic lifetimes is challenging, though careful use of Pandora-type instruments may prove beneficial. A careful intercomparison of Pandora and NIWA's M07 instrument was carried out. Results show Pandora to be well correlated with M07, showing its viability as a validation tool for SAGE science.
The SAGE-III instrument was launched in February 2017. As with any new instrument, a significant...
Share